Mge ups systems, service, and emergency support qps. Ideal for commercial and technical facilities as well as industrial applications, the mge galaxy 3500 includes dualmains input, automatic and maintenance bypasses, and scalable runtime with hotswappable batteries for increased availability. This manual is available in the following languages. The mge galaxy 3500 offers a new way for electrical contractors and facility managers to achieve reliable and costeffective protection for missioncritical applications. Mge galaxy 5000 100120kva complete set spare part kit level 3. All these features make the galaxy 5000 one of the easiest upss in its class to manage and maintain. Our refurbished equipment comes standard with a one year warranty. You can configure all parameters of a switched rack pdu including those for which there are not specific cli commands by using the cli to transfer an. The mge galaxy 5000 offers intelligent energy management via electric ecostruxure hardware and software.
Somerset power systems is a division of somerset capital group, ltd. Enter your postal code or sign in to receive the best value in your area. G55tupsm80hs onduleur mge galaxy 5500 80 kva 400 v. Mge galaxy 5000 40 kva 480 v greensource cincinnati.
To take into account evolving standards and technology, equipment may be modified without notice. Dual input allows for connection to two separate input sources for increased availability. Mge ups systems galaxy 5000 installation manual pdf. This manual comes under the category uninterruptible power supplies upss and has been rated by 1 people with an average of a 8. Galaxy 5000 and galaxy 5500 modbus register map pdf. Table of contents galaxy 5000 at the end of its service life. This specification describes a threephase, online, double conversion, solid state uninterruptible power system hereafter referred to as the ups. Measures that have made mge galaxy 7000 a reference in environmental protection include.
Galaxy 3000 reflected distortion clean power on the input and the output output while most ups provide clean power on the output, the rectifier can reflect distortion back onto the utility power, disturbing other equipment sharing the utility power in the rest of the facility. Ce declaration of conformity mge galaxy 5500 20120kva ups and aux. Mge ups systems announces the galaxy 5000 and galaxy. View the manual for the apc mge galaxy 5000 here, for free. Double conversion online topology compact and robust design. Mge galaxy 5000 20120 kva battery circuit breaker kits installation manual. The maximum number of products that can be compared is 4. This manual comes under the category uninterruptible power supplies upss and has been rated by 1 people with an average of a 6. Mge galaxy 4000 available from 40 75kva, the mge galaxy 4000 ups is robust and able to handle environments that range from medium data centers to industrial and. Igbtbased technology for power quality supplies clean, stable power to sensitive loads, ensuring critical power protection, optimum performance, and extended life. Maximize reliability and efficiency for total lower cost of ownership by utilizing struxureware in order to collect information and make decisions about operation status, assets, and resource use. Page 1 galaxy 5000 20 120 kva battery circuitbreaker cabinet installation manual page 1 34003641fraa page 2. Sps brings together old school quality with todays technical skills we make the buying. Measures that have made mge galaxy 5000 a reference in environmental protection include.
It is the only pdf file viewer that can open and interact with all pdf documents. Remotely the mge galaxy 7000 provides valuable information to supervision systems on. Galaxy 5000 documents and downloads schneider electric. They implement original technology not available to competitors of apc by schneider electric. The maintenance bypass is made up of three manual switches q3bp, q4s and q5n. Mge galaxy pw, mge galaxy 5000, mge galaxy 6000 and mge galaxy 7000 synchronization module installation and user manual prp. Flexible 3 phase power protection designed to meet a wide range of requirements from data centers to industrial and facilities applications. Apc mge galaxy 5000 ups mcfi data center solutions.
G5tups60 mge galaxy 5000 60 kva schneider electric global. Configurable system with a comprehensive range of accessories to meet your application demands. Mge galaxy 3500 10152030 kva performance power protection for critical applications features and benefi ts 10 30 kva compact threephase power protection with excellent effi ciency and optimized footprint, particularly adapted for demanding industrial environments. Data center grade three phase uninterruptible power supply. The recommended power protection for all critical applications. The numbering plan is correct and so is our connection, but the issue is that the 1 and 3 should be the coil command output 24v, meaning the trip coil of the battery breaker i have an external battery cabinet should be high 24v and if there is a trouble it should be 0v, but the situation is that the output on 1 and 3 is always 0v which makes the breaker always tripped. Do you have a question about the apc mge galaxy 3500 20kva 400v or do you need help. Read all instructions in the installation manual before installing or working on this. Pressing the general shutdown button causes ups shutdown and opening of the battery circuit breaker. The apc mge galaxy 3500 offers centralized 3 phase power protection with the reliability of the mge product family.
These new systems are the fruit of 40 years of technological and commercial expertise and incorporate the latest innovations to meet the new challenges of providing high availability power. To discover the entire range of mge ups systems products and the options available for the galaxy 5000 range, we invite you to visit our web site. Download free pdf user manuals for mge ups systems galaxy 3000. View the manual for the apc mge galaxy 3500 20kva 400v here, for free. Mge galaxy 3000 gltt10kg upsbattery backup products. Mge galaxy 5000 with stand alone battery cabinets ups. The ups has been tested and load banked in our brand new state of the art repair facility. The galaxy 3000 is equipped with input power factor correction. The mge galaxy 5000 feathers paralleling capability for both capacity and redundancy as well as full front access, user friendly display and advanced communication management. External bypass cabinet, page 32 or return galaxy 5000 480 v parallel ups.
Free galaxy mge 3000 tuner software download galaxy mge. Configurable system with a comprehensive range of accessories to meet your. Mge galaxy 5000 40 kva 480 v install panels and labels on 48 battery cabinet stand alone only. User manual apc mge galaxy 3500 20kva 400v 40 pages. With its 5,000 timestamped events, statistical analysis, and energy flow pictograms, system management could not be simpler.
338 1599 162 966 360 909 1513 666 1207 1122 1498 1596 485 109 1231 881 1297 645 739 1100 1474 917 338 1351 210 1087 574 1395 1345 1126 351 844 500 272 1315 1083